HIgh Voltage probe HVP-40DM
사양(Spec)
High Voltage probe HVP-40DM
DC 40KV CAT II Pollution 2.
2000MΩ Impedance.
3999 LCD display.
Accuracy 1.0% full range.
T.C. 100 ppm/oC
400V/4KV/40KV, 3 range.
Resolution 0.1V/1V/10V.
PEAK HOLD, Auto power off.
CE, TUV GS, UL, CUL, IEC1010
SPECIFICATIONS ( 20 ± 5℃, RH < 80% )
! WARNING !
측정하기 전, Probe의 악어클립(검정색)을 접지에 꼭 연결하고 사용해야 합니다.
Input impedance : 2000MΩ
Maximum operation voltage : 40KV DC , CAT II , Pollution 2
Polarity : Positive / Negative
Display : 3999 digital, LCD
Accuracy : Full Range ≦ 1.0% ± 2 digital
Temperature Coefficient : ≦ 100ppm / ℃
Maximum loading Current : ≦ 20μA
Maximum loading power : ≦ 0.8 watt
Voltage Range : 40KV / 4KV / 400V / 3 Range
Voltage resolution : 10V / 1V / 0.1V
Power source : 9V / 006P, IEC6L R1, NEDA 1604A
Low battery Indicate : ≦7.3V Auto Indicate
Battery Life : About 200hr ( ALKALI )
Auto power off : About 30 mim
PEAK HOLD : ≧ 400 ms
Sampling : 4 Sampling / sec
Operating temperature : 0 ℃ ~ + 50 ℃
Storage temperature : - 20 ℃ ~ + 70 ℃
Ground lead length : 90cm ( 35 " )
Dimensions : 420 L x 80ψ
Weight : 360g