Frequency Range | 9kHz-30MHz | ||
Frequency resolution | 1Hz | ||
Measurement Accuracy | <1ppm | ||
RF input | 50Ω,SMA fem. | ||
VSWR | 30dB RF att. | <1.2 | |
0dB RF att. | <2 | ||
Attenuation | 0dB—30dB | ||
Measurement Accuracy (Typical) | ±1.5dB | ||
Max Input Level(If equipment is not damaged) | |||
Sinusoidal Voltage | 120dBuV | ||
Density of Impulse Frequency | +97dBμV/MHz | ||
Preselector | |||
Fixed bandpass filter |
LP-150kHz 150kHz-4.05MHz 4.05MHz-12.8MHz 12.8MHz-21.55MHz 21.55MHz-30MHz | ||
IF Bandwidth | |||
6dB | 0.2 and 9kHz (CISPR 16-1-1) |
Displayed average noise level (DANL) | |
9kHz-150kHz (200Hz BW) | <0dBμV(QP) typical |
<-5dBμV(AV) typical | |
150kHz-30MHz (9kHz BW) | <5dBμV(QP) typical |
<0dBμV(AV) typical | |
Detector |
Peak, quasi-peak, CISPR average |
Test Time(Dwell Time) |
PK/AV:5-500ms Adjustable QP:1s-15s Adjustable |
Image Rejection | 90dB typical |
Display Unit | dB μV dBm |
Real time FFT spectrum analyzer mode | 1.5kHz RBW |
Communication port | USB2.0 |
Power Supply | DC12V/1A |
Operating Temperature | 0℃~45℃ |
Size | 193*134*58mm |
Weight | 1kg |