Model | HCP8300A | |
Bandwidth (-3dB) |
DC-8 MHz (Figure10.b) | |
Rise time | ≤50ns | |
Continuous maximum input range |
300Arms (Figure11.b) | |
Max peak current value | 500Apk | |
Range | 50A | 10X |
300A | 100X | |
Overload | 50A | ≥50APk |
300A | ≥500APk | |
Current transfer ratio | 50A | 0.1V/A |
300A | 0.01V/A | |
Measurable current | 50A | 10mA |
300A | 100mA | |
Amplitude accuracy (DC,45-66Hz ) |
50A | ±1%±10mA |
300A | ±1%±100mA | |
Input impedance |
Reference (Figure12.b) | |
Delay time | Probe | 41ns |
BNC (1m) | 5ns | |
Terminal load | ≥100kΩ | |
Power supply | DC 12V/1A(Standard Adaptor) | |
Voltage of insulated wire | 600V CATII 300V CATIII | |
Safety compliance | EN61010-1: 2010+A1:2019 EN 61010-2-032:2019 | |
EMC standard | EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013 |