Model | DP6000(A) | |||||
Bandwidth(-3dB) | DP6700 | 70MHz | ||||
DP6070A | 100MHz | |||||
Rise time | DP6700 | ≤5ns | ||||
DP6700A | ≤3.5ns | |||||
Accuracy | ±2% | |||||
Range selection(Attenuation rate) | 100X/1000X | |||||
Maximum differential voltage(DC + Peak AC) | 100X | ±700V | ||||
1000X | ±7000V | |||||
Common mode voltage(DC + Peak AC) | ±7000V | |||||
Maximum differential mode VS frequency curve | Figure 4 | |||||
Maximum input voltage-to-earth (Vrms) |
1000V CATIII 2300V CATI | |||||
Input impedance | Single-ended to ground |
20MΩ | ||||
Between inputs |
40MΩ | |||||
Input capacitance | Single-ended to ground | <5pF | ||||
Between inputs | <2.5pF | |||||
CMRR | DC | >80dB | ||||
100kHz | >60dB | |||||
1MHz | >50dB | |||||
Noise(Vrms) | 100X | <200mV | ||||
1000X | <1.2V | |||||
Differential overvoltage detection level | 100X | ≥700V | ||||
1000X | ≥7000V | |||||
Propagation time | Probe | About 9ns | ||||
BNC Line(1m) | About 5ns | |||||
Bandwidth limit filters (5MHZ) |
≥-3dB@5MHz | |||||
Overload indicator (red light) | Yes | |||||
Overload alarm | Yes(Can shut up manually) | |||||
Automatic save | Yes | |||||
Offset setting function | Yes( Set in test mode) | |||||
Terminate load |
≥100kΩ | |||||
Power supply | USB 5V/1A adapter | |||||
Safety standard | EN61010-1: 2010 | |||||
EMC standard | EN61326-1:2013 EN61000-3-2:2006+A1:2009+A2:2009 EN61000-3-3:2013 |