Model | HCP8150A | |
Bandwidth (-3dB) |
DC-22MHz (Figure7.b) | |
Rise time | ≤16ns | |
Continuous maximum input range |
150Arms (Figure8.b) | |
Max peak current value | 300Apk | |
Range | 30A | 10X |
150A | 100X | |
Overload | 30A | ≥30APk |
150A | ≥300APk | |
Current transfer ratio | 30A | 0.1V/A |
150A | 0.01V/A | |
Measurable current | 30A | 10mA |
150A | 100mA | |
Amplitude accuracy (DC,45-66Hz ) |
30A | ±1%±10mA |
150A | ±1%±100mA | |
Input impedance |
Reference(Figure9.b) | |
Delay time | Probe | 30ns |
BNC (1m) | 5ns | |
Terminal load | ≥100kΩ | |
Power supply | DC 12V/1A(Standard Adaptor) | |
Voltage of insulated wire | 600V CATII 300V CATIII | |
Safety compliance | EN61010-1: 2010+A1:2019 EN 61010-2-032:2019 | |
EMC standard | EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013 |